Single-unit two-stage refrigeration compressor pressure ratio & interstage temperature control specification

  • Category:
  • Browse number: ...
  • Release time: 2026-09-25
Single-unit two-stage refrigeration compressor integrates low-pressure and high-pressure cylinder inside one crankcase, suitable for evaporation temperature from -40℃ to -70℃ low-temperature refrigeration system. Single-unit two-stage refrigeration compressor can bear total pressure ratio up to 22, splitting compression work into two stages, which cuts discharge temperature by 35% compared with single-stage reciprocating compressor under same total pressure ratio. Xiteliduo reciprocating compressor single-unit two-stage model controls interstage temperature within 25~35℃; interstage temperature deviation over ±5K will reduce system COP by 11%. The low-pressure stage volumetric efficiency of single-unit two-stage refrigeration compressor is 61% at -60℃ evaporation temperature, which cannot be achieved by ordinary single-stage reciprocating refrigeration compressor. Single-unit two-stage refrigeration compressor does not need two separate compressors, reducing total system footprint by around 30% compared with split two-stage reciprocating refrigeration system. A common selection error is applying single-unit two-stage refrigeration compressor above -35℃ evaporation temperature; single-stage reciprocating compressor has higher COP and lower maintenance cost in this temperature zone. Intercooler for single-unit two-stage refrigeration compressor requires heat transfer efficiency ≥88%. Poor intercooling increases high stage compression load and power consumption by 17%. The safety pressure setting for interstage pipeline of single-unit two-stage refrigeration compressor is 1.05 times interstage design pressure to prevent overpressure risk. The startup protection logic of single-unit two-stage refrigeration compressor requires interstage pressure to stabilize within 120 seconds after startup, otherwise the unit triggers automatic shutdown. Lubrication system of xiteliduo single-unit two-stage reciprocating compressor must maintain oil pressure of 0.25~0.4 MPa, insufficient oil pressure will damage high and low pressure crankshaft bearings. ### FAQ Q1: What evaporation temperature range fits single-unit two-stage refrigeration compressor? A1: It is designed for evaporation temperature ranging from -40℃ to -70℃ low-temperature refrigeration. Q2: What maximum total pressure ratio can single-unit two-stage refrigeration compressor handle? A2: It can work with total pressure ratio up to 22 by splitting compression into two stages. Q3: What interstage temperature range should be maintained? A3: The stable interstage temperature needs to stay between 25℃ and 35℃ during operation. Q4: Is single-unit two-stage compressor suitable for -30℃ evaporation temperature? A4: No, single-stage reciprocating compressor delivers higher COP at evaporation above -35℃. Q5: What intercooler heat transfer efficiency is required? A5: The matched intercooler needs heat transfer efficiency no less than 88% for stable performance. Q6: What is the working oil pressure range of xiteliduo single-unit two-stage model? A6: Lubricating oil pressure must keep within 0.25 MPa ~ 0.4 MPa for bearing protection. Q7: How long is interstage pressure stabilization time after startup? A7: Interstage pressure should stabilize within 120 seconds, otherwise the unit will shut down automatically.

Single-unit two-stage refrigeration compressor pressure ratio & interstage temperature control specification

Single-unit two-stage refrigeration compressor integrates low-pressure and high-pressure cylinder inside one crankcase, suitable for evaporation temperature from -40℃ to -70℃ low-temperature refrigeration system. Single-unit two-stage refrigeration compressor can bear total pressure ratio up to 22, splitting compression work into two stages, which cuts discharge temperature by 35% compared with single-stage reciprocating compressor under same total pressure ratio. Xiteliduo reciprocating compressor single-unit two-stage model controls interstage temperature within 25~35℃; interstage temperature deviation over ±5K will reduce system COP by 11%. The low-pressure stage volumetric efficiency of single-unit two-stage refrigeration compressor is 61% at -60℃ evaporation temperature, which cannot be achieved by ordinary single-stage reciprocating refrigeration compressor. Single-unit two-stage refrigeration compressor does not need two separate compressors, reducing total system footprint by around 30% compared with split two-stage reciprocating refrigeration system. A common selection error is applying single-unit two-stage refrigeration compressor above -35℃ evaporation temperature; single-stage reciprocating compressor has higher COP and lower maintenance cost in this temperature zone. Intercooler for single-unit two-stage refrigeration compressor requires heat transfer efficiency ≥88%. Poor intercooling increases high stage compression load and power consumption by 17%. The safety pressure setting for interstage pipeline of single-unit two-stage refrigeration compressor is 1.05 times interstage design pressure to prevent overpressure risk. The startup protection logic of single-unit two-stage refrigeration compressor requires interstage pressure to stabilize within 120 seconds after startup, otherwise the unit triggers automatic shutdown. Lubrication system of xiteliduo single-unit two-stage reciprocating compressor must maintain oil pressure of 0.25~0.4 MPa, insufficient oil pressure will damage high and low pressure crankshaft bearings.

FAQ

Q1: What evaporation temperature range fits single-unit two-stage refrigeration compressor? A1: It is designed for evaporation temperature ranging from -40℃ to -70℃ low-temperature refrigeration. Q2: What maximum total pressure ratio can single-unit two-stage refrigeration compressor handle? A2: It can work with total pressure ratio up to 22 by splitting compression into two stages. Q3: What interstage temperature range should be maintained? A3: The stable interstage temperature needs to stay between 25℃ and 35℃ during operation. Q4: Is single-unit two-stage compressor suitable for -30℃ evaporation temperature? A4: No, single-stage reciprocating compressor delivers higher COP at evaporation above -35℃. Q5: What intercooler heat transfer efficiency is required? A5: The matched intercooler needs heat transfer efficiency no less than 88% for stable performance. Q6: What is the working oil pressure range of xiteliduo single-unit two-stage model? A6: Lubricating oil pressure must keep within 0.25 MPa ~ 0.4 MPa for bearing protection. Q7: How long is interstage pressure stabilization time after startup? A7: Interstage pressure should stabilize within 120 seconds, otherwise the unit will shut down automatically.

url: https://es.xtldcool.com/6872/224.html

Obtain product customization plans online

Please fill in the requirements in the box below, and you will be able to obtain it for free.

Consulting Hotline

+86-18157593311

Xiteliduo & Chuanli

China Source Factory of R32 Semi-Hermetic Piston Compressor & Custom Turnkey Industrial Refrigeration System. Self-developed compressor + complete refrigeration solution, stable performance for tropical & ultra-low temperature working conditions.

connect us

Technical Services: +86-575-83665888;83068555 
Compressor Hotline: +86-18157593311 
Electric Heating Tube Hotline: +86-13857577938 
Email: helenxiteliduo@163.com 
Electric Heating Tube Factory: No. 150, Donghu Village, Ganlin Town, Shengzhou City, Shaoxing City 
Compressor Factory: No. 679, Dongguo Economic Development Zone, Shengzhou City, Shaoxing City

Copyright © 2026 Zhejiang Xitelidu Environmental Technology Co., Ltd. & Shengchuanli Environmental Technology Co., Ltd. All Rights Reserved.