Piston Refrigeration Compressor Cross Contamination Risk | System Flushing after Motor Burnout

Motor burnout induced acid contamination causes 40% of replacement compressor secondary failure, xiteliduo Refrigeration Compressors provides acid cleaning procedure. Piston refrigeration compressor burnout will produce acid, carbon particles and sludge, which remain in evaporator, condenser and pipeline. Semi-hermetic refrigeration compressor system after motor burnout requires multiple filter-drier replacement until acid test result is qualified. Cold storage refrigeration compressor acid test kit must be used to verify system cleanliness. Acid number must be less than 0.05 mgKOH/g before new compressor installation. Contaminated refrigerant cannot be reused directly; it must be recovered, recycled and purified or discarded in compliance with environmental regulations. 10 recommended hot search keywords: cold storage refrigeration compressor, piston refrigeration compressor, semi-hermetic refrigeration compressor, refrigeration compressor motor burnout, refrigeration system acid contamination, refrigeration filter drier replacement, refrigeration acid test, refrigeration compressor manufacturer, cold storage compressor system cleaning, refrigeration compressor supplier

FAQ

Q1: What percentage of new compressors fail again due to residual acid contamination? A: 40% of replacement compressors suffer secondary failure caused by acid contamination. Q2: What pollutants are generated after compressor motor burnout? A: Acid, carbon particles and oil sludge retained in the whole refrigeration circuit. Q3: What operation must be repeated for burnt semi-hermetic system? A: Replace filter drier repeatedly until acid test passes. Q4: What acid number acceptance standard before installing new compressor? A: Acid number less than 0.05 mgKOH/g. Q5: Can contaminated refrigerant be reused directly? A: No, it needs recovery, purification or compliant disposal. Q6: What will happen if new compressor is installed without acid cleaning? A: Acid will corrode winding and bearings, leading to repeated burnout. Q7: What tool is used to detect acid inside refrigeration system? A: Refrigeration system acid test kit.

url: https://es.xtldcool.com/news/460.html

Obtain product customization plans online

Please fill in the requirements in the box below, and you will be able to obtain it for free.

Consulting Hotline

+86-18157593311

Xiteliduo & Chuanli

China Source Factory of R32 Semi-Hermetic Piston Compressor & Custom Turnkey Industrial Refrigeration System. Self-developed compressor + complete refrigeration solution, stable performance for tropical & ultra-low temperature working conditions.

connect us

Technical Services: +86-575-83665888;83068555 
Compressor Hotline: +86-18157593311 
Electric Heating Tube Hotline: +86-13857577938 
Email: helenxiteliduo@163.com 
Electric Heating Tube Factory: No. 150, Donghu Village, Ganlin Town, Shengzhou City, Shaoxing City 
Compressor Factory: No. 679, Dongguo Economic Development Zone, Shengzhou City, Shaoxing City

Copyright © 2026 Zhejiang Xitelidu Environmental Technology Co., Ltd. & Shengchuanli Environmental Technology Co., Ltd. All Rights Reserved.